In this paper we have shown that, if the noise of the polarimeters
have nearly equal levels and are approximately uncorrelated, these detectors
can be set up in "Optimised Configurations''. These
configurations are optimised in two respects: first the volume of the
error ellipsoid is minimised, and second the
error matrix of the inferred Stokes parameters is approximately
diagonal in all reference frames. This remains true even if one
combines information from numerous measurements along different
scanning circles. Such "Optimised Configurations'', with 3 and 4 polarimeters, have
been proposed by the Planck High Frequency Instrument consortium
(HFI Consortium, 1998) for the three channels where it is intended to
measure the CMB polarisation.