CCDs have been used in astrometry for several years,
e.g. for the determination of parallaxes, double stars and
for meridian circle observations (see references in Geffert 1998).
However most of these observations are based on CCD observations
with fields of
and smaller.
Since our study uses CCD observations of fields with a size at least
20
20
it seems necessary to evaluate the accuracy,
which may be obtained with such telescope detector combinations.
While the CCD frames of Calar Alto were already tested in an earlier study
(Geffert et al. 1994), we will concentrate here on the Hoher List observations.
In a first step we have compared positions of stars from pairs of CCD frames.
The positions of one frame were transformed by an affine transformation
to a second frame and the rms of the differences were calculated
for each coordinate.
Under the assumption that both frames contribute with equal weight to the
differences, we have calculated from the rms the mean uncertainty of one
position on one frame.
These are given in Table 4 for several CCD pairs
with nearly identical limiting magnitudes.
In this comparison we included all stars which were detected
on the CCD frames.
Frames |
![]() |
![]() |
Lim. mag. | No. of stars |
[mas] | [mas] | (V) | ||
4236/4237 | 62 | 64 | 16.5 | 1373 |
4238/4239 | 120 | 120 | 18.5 | 3378 |
4240/4241 | 63 | 67 | 16.2 | 1081 |
4242/4243 | 100 | 80 | 17.0 | 1980 |
In a second test we consider only the stars which contribute to the final catalogue of our investigation. These are stars at the brighter end of the magnitude distribution. Reducing the plates with one catalogue (ACT or Hipparcos) leads to positions of the stars of each plate/CCD frame in a common system. The position and proper motion of each star in our final solution described in Sect. 2 are determined by a fit to the positions and epochs of the different plates/CCD frames for each star. The mean position and proper motion of each star is then used to update the positions of each star for the epoch of the individual plates/CCD frames. For each plate the mean and rms of the positional differences from the initial positions are determined. The rms will give an indication of the accuracy of each individual plate/CCD frame. Table 5 summarizes for the Hoher List frames the mean and standard deviations for each frame.
CCD frame |
![]() |
![]() |
![]() |
![]() |
Colour |
[mas] | [mas] | [mas] | [mas] | ||
4236 | +10 | 70 | -7 | 90 | B |
4237 | +6 | 70 | -5 | 70 | B |
4238 | +7 | 80 | 0 | 90 | B |
4239 | +6 | 100 | +2 | 50 | B |
4240 | +7 | 80 | 0 | 50 | V |
4241 | -2 | 40 | -1 | 50 | V |
4242 | -0 | 90 | +5 | 50 | V |
4243 | +3 | 40 | +6 | 90 | V |
Table 5 shows a slight difference in the B and V frames of the order of a few mas. Nevertheless the systematic deviations between the B and V frames are small. The positional accuracy of each star is of the order of one tenth of a pixel. This value is a little bit larger with respect to other studies (e.g. Geffert 1998). The reason may be the crowding in the region of M 10. In general, the accuracy of one single frame is of the order of the accuracy of one refractor plate, which justfies the use of CCD frames for the second epoch observation.
Copyright The European Southern Observatory (ESO)